Water Quality

Managing Bromate Risk During Ozone Disinfection

Review source chemistry, disinfection performance, formation controls, trials and monitoring before setting an ozone operating window.

Published October 9, 2026

Assess formation risk before specifying ozone

Ozone can disinfect water, but it can also convert bromide in the water into bromate. For a bottled-water project, this makes source-water testing part of treatment design. WHO notes that bromate is difficult to remove once formed, so controlling formation deserves attention before selecting an ozone generator or finalizing operating settings.

WHO gives bromate a provisional drinking-water guideline value of 0.01 mg/L, equivalent to 10 micrograms per litre. In the United States, EPA lists a bromate maximum contaminant level of 0.010 mg/L under its public drinking-water regulations. These values must be read in their proper scope. A bottled-water producer must separately confirm the requirements for its product and destination markets; public-system compliance procedures should not automatically be presented as bottled-water release rules.

Five steps for evaluating the treatment process

  1. Build a representative water profile

    Test bromide, pH, alkalinity and dissolved organic carbon in the water that will actually enter ozonation. Bromate formation depends on these characteristics as well as ozone dosage. Include samples that represent meaningful source-water variation rather than relying on a single report.

  2. Define the required disinfection performance

    Establish the microbial treatment objective before adjusting ozone. Where concentration–contact time, or CT, is used, assess dissolved ozone and effective contact time under the relevant conditions. Generator output alone does not demonstrate that water received the required treatment. EPA guidance emphasizes ozone demand, decay and contact-time limitations when evaluating dose changes.

  3. Evaluate controls as a complete treatment process

    Lower ozone exposure or a lower ozonation pH may reduce bromate formation. However, reducing ozone must preserve the required disinfection performance, and changing pH can affect materials, treatment chemistry and other byproducts. Ammonia-based controls discussed in municipal guidance introduce additional considerations, including nitrification; they require specialist assessment rather than routine adoption in a bottling plant.

  4. Run tests before fixing the operating window

    Use representative water in bench or pilot trials to compare candidate settings. Measure bromate alongside the variables needed to verify disinfection. EPA guidance identifies bench and pilot studies as tools for selecting suitable treatment where source chemistry creates byproduct concerns. There is no single ozone dose that guarantees acceptable bromate for every water source.

  5. Plan monitoring and responses

    Document sampling points, laboratory methods, operating limits and actions for abnormal results. An engineering review should consider changes in water source, temperature, throughput and treatment settings. Monitoring should support both process control and the product’s applicable verification requirements, with responsibilities and response actions defined before operation.

Connect the treatment review to the bottling line

Before specifying water-treatment equipment, assemble the water analysis, required production rate and applicable product requirements. These inputs support evaluation of the treatment train within a turnkey water-production project. Review the final treated-water interface with the selected PET water filling machine.

Prepare these inputs for pre-sale technical review and include them in a project inquiry so treatment assumptions can be reviewed explicitly.

References

  1. WHO: Bromate Chemical Fact Sheet
  2. EPA: National Primary Drinking Water Regulations
  3. EPA: Disinfectants and Disinfection Byproducts Rules — Plain English Guide
  4. EPA: Simultaneous Compliance Guidance Manual, Section 5.2 (2007)
  5. EPA: Alternative Disinfectants and Oxidants Guidance Manual (1999)